6es7972-0cb20-0xa0

6es7972-0cb20-0xa0 vs 6gk1571-0ba00-0aa0

6GK1571-0BA00-0AA0

PC adapter USB A2 USB adapter (USB V2.0) for connection of a PG/PC or notebook to SIMATIC S7 via PROFIBUS or MPI contains USB cable 5 m, MPI cable 0.3 m can be used under Windows XP/Vista/ Windows 7 32/64-bit and higher

6ES7972-0CB20-0XA0

Siemens usb-mpi s7-200/300/400 plc cable 6es7972-0cb20-0xa0

SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7;
WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT

6es7972-0cb20-0xa0 manual

Use 6ES7 972-0CB20-0XA0 (PC ADAPTER USB) to download the s7-300 / 400 plc program, but the driver cannot be installed.

6es7972-0cb20-0xa0 cable

Solution: Download the PC Adapt USB driver file

usb mpi driver install

Find the driver file and copy it to C: \ Program Files \ Common Files \ Siemens \ Automation \ Simatic OAM \ Drivers

Then open “Device Manager”, select “SIMATIC PC Adapter USB”, right-click, and select “Browse my computer for computer driver software”

siemens pc adapter usb 6es7972 0cb20 0xa0 driver,

Select the folder (C: \ Program Files \ Common Files \ Siemens \ Automation \ Simatic OAM \ Drivers) and click Next:

siemens pc adapter usb 6es7972 0cb20 0xa0 driver,

Then the driver will be installed automatically

siemens simatic s7 pc adapter usb 6es7972-0cb20-0xa0 driver

Now the drive has been successful installation, return to the “Device Manager.” Seeing the yellow warning is gone.

siemens simatic s7 pc adapter usb 6es7972-0cb20-0xa0 driver
siemens simatic s7 pc adapter usb 6es7972-0cb20-0xa0 driver

6ES7 972-0CB20-0XA0(PC ADAPTER USB)

SIEMENS USB TO MPI(6es7-972-0cb20-0xa0) Driver Download windows 10

Note

When installing the driver (the software SETP7 is above V5.5, no driver is required, remember), for the problem of repeated requests to restart, you can modify the computer’s registry as follows:

  1. Click the “Start” menu of the computer, find “Run”, and enter “regedit” in the pop-up window. After confirming, you can find the computer registry and delete it according to the following method:
  2. Find the “HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager\” in the registry, delete the registry value “PendingFileRenameOperations” and install the driver without restarting.

*amsamotion mpi driver is same as siemens usb to mpi driver

How does the connection with Siemens S7-200/300/400 PLC?

38 thoughts on “6es7972-0cb20-0xa0”

  1. it works with win 10 for MPI only can’t work with profibus always not working with it can you help me i need to work with profibus

    Reply
  2. I bought the version SEMIES S7-300, I can run it on Windows XP but not in Windows 10. Do I have to reinstall any drivers?

    Reply
  3. Dear sir,
    How to am purchase?
    How much of Indian money?
    This cable support? Windows XP sp3 os

    Please replay me sir

    WhatsApp: 978*68667
    Mail: maruthu3*90@gmail.com

    Reply
  4. I cannot get my 6ES7972-0CB20-0XA0 to work. I have downloaded drivers and tried installed. Still not working.
    All I see is this:
    Online: The local MPI address for the programming device/PC is higher than the maximum device address or the wrong transmission rate or wrong interrupt is set.
    I ma running windows 10.
    HELP

    Reply
  5. I am using Win 10 pro but installation failed.
    I copied drivers to the mentioned directory but windows refused the installation.

    What should I do

    Reply
  6. Hello
    6es7972-0cb20-0xa0 is not installed. Installation is performed on VMware® Workstation 12 Pro running Windows 7 Pro Service Pack1. What drivers are needed for this?

    Reply
    • Hello,

      I have bought your 6GK1 571-0BA00-0AA0 PC ADAPTER USB A2, and installed drivers from the internet, and it shows in device manager as usb pc adapter but when I try to connect to PLC s7-200 with simatic step7 v4.0 i cant conect because it requires to set com port in pg pc , but I only have usb .
      Help please!

      Reply
  7. Tried to install on w10 but got the following error

    your system has not been modified. to complete installation at another time please run setup again

    Could you give me an idea to solve the problem?

    Reply
  8. My pc adapter usb A2 (6GK1 571-0BA0-0AA0) it’s not recongised on my pc, windows 10 x64, even the led’s thosen’t work at all. What can it be and how can i fix this issue???
    Thank’s

    Reply
  9. Mine stop working when copying many blocks(more than a thousand) from online to offline backup. Need unplug and plug the usb and copy in small batches. What’s wrong with the adapter?

    Reply
  10. Better to buy an original Siemens MPI adapter. My amsamotion mpi adapter will stop during copying of blocks(if copying over a thousand blocks), the mpi led will go off, I need to unplug and re-plug it to work again.

    Reply
  11. hello,

    i have received the cable but when i try to connect to plc s7-315-2dp it shows the following error. ” the local mpi address for the programming device / pc is higher than the maximum node address or the wrong transmission rate or wrong interrupt is set ”

    kindly help me out .

    some time it gives error ” unable to establish a connection to module cpu “

    Reply