6GK1571-0BA00-0AA0
PC adapter USB A2 USB adapter (USB V2.0) for connection of a PG/PC or notebook to SIMATIC S7 via PROFIBUS or MPI contains USB cable 5 m, MPI cable 0.3 m can be used under Windows XP/Vista/ Windows 7 32/64-bit and higher
6ES7972-0CB20-0XA0
Siemens usb-mpi s7-200/300/400 plc cable 6es7972-0cb20-0xa0
SIMATIC S7, PC ADAPTER USB F. CONNECTION OF S7-200/300/ 400, C7;
WITH USB-CABLE (5M) CAN BE USED UNDER WINXP/VISTA/ WINDOWS 7 32/64BIT
6es7972-0cb20-0xa0 manual
Use 6ES7 972-0CB20-0XA0 (PC ADAPTER USB) to download the s7-300 / 400 plc program, but the driver cannot be installed.

Solution: Download the PC Adapt USB driver file
Find the driver file and copy it to C: \ Program Files \ Common Files \ Siemens \ Automation \ Simatic OAM \ Drivers
Then open “Device Manager”, select “SIMATIC PC Adapter USB”, right-click, and select “Browse my computer for computer driver software”

Select the folder (C: \ Program Files \ Common Files \ Siemens \ Automation \ Simatic OAM \ Drivers) and click Next:

Then the driver will be installed automatically

Now the drive has been successful installation, return to the “Device Manager.” Seeing the yellow warning is gone.


6ES7 972-0CB20-0XA0(PC ADAPTER USB)
SIEMENS USB TO MPI(6es7-972-0cb20-0xa0) Driver Download windows 10
Note
When installing the driver (the software SETP7 is above V5.5, no driver is required, remember), for the problem of repeated requests to restart, you can modify the computer’s registry as follows:
- Click the “Start” menu of the computer, find “Run”, and enter “regedit” in the pop-up window. After confirming, you can find the computer registry and delete it according to the following method:
- Find the “HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Session Manager\” in the registry, delete the registry value “PendingFileRenameOperations” and install the driver without restarting.
*amsamotion mpi driver is same as siemens usb to mpi driver
How does the connection with Siemens S7-200/300/400 PLC?
Hello, I bought your product, how can I run it in windows 10?
6ES7 972-OCB20-0XAO
support
the download link:
https://www.amsamotion.store/product/6es7972-0cb20-0xa0-2
did not work anymore, could you fix the problem?
It’s impossible to Download manuals and Drivers
https://www.amsamotion.store/product/6es7972-0cb20-0xa0
fixed
it works with win 10 for MPI only can’t work with profibus always not working with it can you help me i need to work with profibus
your cable need support profibus
I bought the version SEMIES S7-300, I can run it on Windows XP but not in Windows 10. Do I have to reinstall any drivers?
the cable support windows 10,please check your setting and driver
Hello, drivers are not recognized on my Windows 10 64 bits computer
Try to restart the computer or reinstall windows10
This cable support windows XP sp3
yes.
Dear sir,
How to am purchase?
How much of Indian money?
This cable support? Windows XP sp3 os
Please replay me sir
WhatsApp: 978*68667
Mail: maruthu3*90@gmail.com
You can buy from aliexpress shop
Thanks Sir
I cannot get my 6ES7972-0CB20-0XA0 to work. I have downloaded drivers and tried installed. Still not working.
All I see is this:
Online: The local MPI address for the programming device/PC is higher than the maximum device address or the wrong transmission rate or wrong interrupt is set.
I ma running windows 10.
HELP
There are several situations where this problem occurs:
The MPI address setting conflicts with the MPI address of other devices
The MPI communication rate is set incorrectly
PG/PC settings are incorrect
Yeah but i have the same problem when i used a original cable it works perflety. This 6ES7972-0CB20-0XA0 cant work with CPU 224XP?
it support cpu224xp
I am using Win 10 pro but installation failed.
I copied drivers to the mentioned directory but windows refused the installation.
What should I do
Close antivirus software
Hello
6es7972-0cb20-0xa0 is not installed. Installation is performed on VMware® Workstation 12 Pro running Windows 7 Pro Service Pack1. What drivers are needed for this?
Does not support virtual system
Hello,
I have bought your 6GK1 571-0BA00-0AA0 PC ADAPTER USB A2, and installed drivers from the internet, and it shows in device manager as usb pc adapter but when I try to connect to PLC s7-200 with simatic step7 v4.0 i cant conect because it requires to set com port in pg pc , but I only have usb .
Help please!
Tried to install on w10 but got the following error
your system has not been modified. to complete installation at another time please run setup again
Could you give me an idea to solve the problem?
It is best to use a system without any modifications.
My pc adapter usb A2 (6GK1 571-0BA0-0AA0) it’s not recongised on my pc, windows 10 x64, even the led’s thosen’t work at all. What can it be and how can i fix this issue???
Thank’s
maybe broken
Mine stop working when copying many blocks(more than a thousand) from online to offline backup. Need unplug and plug the usb and copy in small batches. What’s wrong with the adapter?
Better to buy an original Siemens MPI adapter. My amsamotion mpi adapter will stop during copying of blocks(if copying over a thousand blocks), the mpi led will go off, I need to unplug and re-plug it to work again.
hello,
i have received the cable but when i try to connect to plc s7-315-2dp it shows the following error. ” the local mpi address for the programming device / pc is higher than the maximum node address or the wrong transmission rate or wrong interrupt is set ”
kindly help me out .
some time it gives error ” unable to establish a connection to module cpu “
Please provide a picture of your product or contact your seller
Hello, I bought your product, how can I run it withe my virtuel machine instaling in my camputer
don’t use virtuel machine
Which VM are you using?
VM version 16
Doesn’t work with Step7 5.6 on Windows 10
it support this version