Sale!

Smart 200 Signal Board

$15.00$68.00

PLC S7-200 SMART Signal Board adds rich resources and simplicity to your industrial automation setup. Explore now!

Description

SMART Signal Board, seamlessly compatible with SIMATIC S7-200 PLC. Experience the same user-friendly interface with added versatility, lower pricing, and enhanced resources.

Key Features:

Rich variety of models
Competitive Pricing
User-friendly design
Seamless compatibility with SIMATIC S7-200 PLC
Abundant resources for diverse applications

Interface Information:
Compatible with SIMATIC S7-200 Smart PLC
Intuitive and easy-to-use interface

Elevate your productivity with our SMART Signal Board, offering a simplified user experience and advanced features. Whether you’re a beginner or an expert, our signal board provides a seamless integration with SIMATIC S7-200 PLC, making it an ideal choice for diverse applications.




Instructions
SMART signal board, rich in resources and easy to use
You only need to configure SBCM01
Analog input address mapping starts with IW600 Analog output address mapping starts with QW600
Just read and write the mapped address directly

 

 

Features Original SMART SMART
Product Type Single, only four or five types More diverse, around 20 types
Configuration Model-dependent SB CM01
Library Not required Not required
Write Commands Not required Not required
Starting Address Fixed Fixed(Starting from IW600, QW600)
Ease of Use Easy Easy
Stability Same Same

Communication Signal Boards

Description Communication Port Connection Method Power Supply
SB CM01 1 RS485 (or 1 RS232) Direct Connection Not required
SB CM02 1 RS485 (no RS232) Direct Connection Not required

Digital Input Signal Boards

Description Digital Inputs Connection Method Power Supply
SB DE02 2 channels Digital Input Direct Connection Not required
SB DE04 4 channels Digital Input PLINK Not required
SB DE06 6 channels Digital Input PLINK Not required
SB QT02 2 channels Output((Transistor) Direct Connection  required
SB QT04 4 channels Output(Transistor) PLINK required
SB QT06 6 channels Output((Transistor) PLINK required
SB DT04 2 channels Digital Input + 2 channels Transistor Output Direct Connection required

Analog Input Signal Boards

Model Description Connection Method Power Supply
SB AE01 Analog input, 1 channel (Voltage and Current) PLINK Not required
SB AE02 Analog input, 4 channels (Voltage and Current) PLINK Not required
SB AE04 Analog input, 4 channels (Voltage and Current) PLINK Not required
SB AE06 Analog input, 2 channels (Voltage and Current) PLINK Not required

Analog Output Signal Boards

Model Description Connection Method Power Supply
SB AE01 Analog input, 1 channel (Voltage or Current) PLINK Not required
SB AE02 Analog input, 2 channels (Voltage or Current) PLINK Not required
SB AE03 Analog input, 4 channel (Voltage or Current) PLINK Not required
SB AE06 Analog input, 6 channel (Voltage or Current) PLINK Not required
SB AQ01 Analog output, 1 channel (Voltage and Current) PLINK Not required
SB AQ02 Analog output, 2 channels (Voltage and Current) PLINK Not required
SB AQ04 Analog output, 4 channels (Voltage and Current) PLINK Required
SB AM03 Analog input (2 channels) (Voltage or Current), Analog output (1 channel) (Voltage and Current) PLINK Not required
SB AM04 Analog input (2 channels) (Voltage or Current), Analog output (2 channels) (Voltage and Current) PLINK Not required
SB AM05 Analog input (4 channels) (Voltage or Current), Analog output (1 channel) (Voltage and Current) PLINK Not required
SB AM06 Analog input (4 channels) (Voltage or Current), Analog output (2 channels) (Voltage and Current) PLINK Not required

Temperature Acquisition Signal Boards

Model Description Connection Method Power Supply
SB AR02 2-channel temperature PT100 acquisition PLINK Not required
SB AR04 4-channel temperature PT100 acquisition PLINK Not required
SB AN04 4-channel temperature NTC (10K, 3950) acquisition PLINK Not required
SB AN06 6-channel temperature NTC (10K, 3950) acquisition PLINK Not required
SB AT04 4-channel K-type thermocouple temperature acquisition PLINK Not required

Frequently Asked Questions
•Q: When the signal board is plugged in, the LINK indicator light does not light up.
Answer: The LINK indicator light is used to indicate normal communication. It will stay on only after the configuration settings are correct and the system blocks are downloaded to the PLC. Off, indicating setting error or equipment failure.
•Q: Do I need to install the library? Is additional programming required?
Answer: No need. unnecessary.
•Q: Can the analog channel directly read the AIW and AQW registers?
Answer: No, it is remapped to the IW and Qw areas and can be read directly.

Additional information

Weight 0.3 kg
Type

SB AE02, SB AE04, SB AM03, SB AM04, SB AQ04, SB CM01, SB CM02, SB DT04, SB AM06, SB AN04, SB DE02, SB DE04, SB DE06, SB QT02, SB QT04, SB QT06, SB DT04, SB AM05, SB AE01, SB AE06, SB AQ01, SB AQ02, SB AR02, SB AR04, SB AN06, SB AT04

Reviews

There are no reviews yet.

Be the first to review “Smart 200 Signal Board”

You may also like…

Worldwide Free Shipping is guaranteed to global online consumers in AMSAMOTION.STORE. We guarantee total shopping satisfaction by offering exchange, Return or Refund Policy.